SHATOX SX-150 portable octane/cetane analyzer
SHATOX SX-150
The SX-150 analyzer is designed for testing fuel quality. It is a portable small-sized device intended for rapid analysis of oil products quality in field and laboratory conditions.
It is an upgraded generation of fuel analyzers that superseded SX-200 and was designed on the basis of SX-300 analyzer.
SX-150 has additional modes for determining gasoline oxidation breakdown time and kerosene percentage in diesel fuel.
The device can be used together with a PC or a laptop through a USB interface. SX-150 supports the automatic computer-based calibration. Measurement results, including the analysis date and time, can be saved in the instrument memory and transferred to the PC (in .xlsx or .txt format).
SX-150 has an 8-key antiglare keyboard, which is easy for operation, wear-proof and resistant to aggressive environments.
The software for the instrument can be downloaded from the manufacturer’s website www.shatox.com in Download section.
Operating conditions: air temperature range from -10°С up to +45°С.
The device is powered from 4 elements of АА type (R6) or from a computer USB port.
Instrument capabilities:
- Gasoline octane level in compliance with ASTM D 2699-86, ASTM D 2700-86.
- Diesel fuel cetane level in compliance with ASTM D 4737-03, ASTM D 613, EN ISO 5165.
- Diesel fuel type and сold filter plugging point (СFPP) (reference parameter).
- Kerosene percentage in diesel fuel (reference parameter).
- Gasoline breakdown time (oxidation stability) (reference parameter).
Parameter description | Measurement units | Value |
Range of measured gasoline octane level |
ON |
40–135 |
Acceptable limit of octane number measurement basic error, max |
ON |
± 0.5 |
Limit of acceptable difference between parallel octane number measurements, max |
ON |
± 0.2 |
Petrol oxidation breakdown time measurement range |
min. |
50-2400 |
Acceptable basic error limit of petrol oxidation breakdown time |
min. |
10 |
Range of measured cetane level |
CN |
20–100 |
Acceptable basic error limit of cetane numbers, max |
CN |
±1.0 |
Acceptable difference limit between cetane numbers parallel measurements, max |
CN |
± 0.5 |
Acceptable error limit when determining СFPP |
C o |
± 5 |
Kerosene content determination range in diesel fuels |
% |
0-95 |
Acceptable basic error limit when determining kerosene content in diesel fuels |
% |
3 |
Measurement time |
sec |
1–5 |
Insufficient power supply indication operation threshold |
V |
5.4 |
Instrument useful life |
Years, minimum |
6 |
Overall dimensions of: |
|
|
electronic module |
mm |
211x100x45 |
sensor #1 |
mm |
60х100 |
Instrument mass with a sensor |
gr |
680 |
Delivery package:
Electronic computing module
Detector #1
Sample imitator
mini-USB cable
Operations manual
Certification
Warranty certificate
Tool canvas bag